Electric Motor: 460/575 volt, Nema T-frame, C-face, open drip proof squirrel cage induction type.
- Motor Starter: 460 volt (40-60 H.P.), full voltage magnetic starter with 110 volt controls, Nema-1 enclosure, ETL listed and three phase overload with external reset and phase protection. Control circuit breaker protection. Other voltages available. Cooling fan protected by overload relay.
- Separator Tank: ASME coded 200 PSIG tank, relief valve, minimum pressure/check valve, high efficiency replaceable oil separator element.
- Fluid Fill & Level Elbow: One piece fluid fill elbow and level sight glass. Vented cap for pressure release when filling.
- Protective Devices: Class 20 overload relay, high temperature and over pressure shutdown switches, and anti-restart pressure switch preventing starting while air compressor is pressurized. Anti-reversing control standard.
- Cooling System: Cooling system with own motor. Large side by side oil cooler/aftercooler. Updraft for maximum efficiency. Easy cleaning.
- HD Air Intake Filter:
Oversized dry type, single stage with replaceable elementInlet Valve: One piece housing for dependable performance and full modulation.
- Coupling & Drive: Compressor is flange mounted to motor C-face for positive alignment and direct driven by zero maintenance coupling.
- Controls: Full modulation, solenoid controlled for smooth lowest possible no load power. Automatic start/stop or constant speed. Timed dual control.
- Instrumentation: Line pressure gauge, discharge pressure gauge, hour meter, temperature gauge, oil filter and separator element differential gauges.
- Auto/Dual Control: Compressor control that allows the unit to be operated in continuous run mode or with an automatic timed shut down. Auto control allows multiple machines to be operated in a lead-lag condition.
- Microprocessor Control.
- Air Cooled Aftercooler: Double pass air-cooled aftercooler with thermostatic control for maintaining the appropriate oil operating temperature and reducing the discharge air temperature to within 15 degrees of ambient.
- Oil Filter: Spin on type mounted direct to compressor unit for ease of maintenance and streamlined tubing.
| Type Name | Industrial Air Compressors |
| Capacity, ACFM: | 210 |
| Maximum Full Load(psiq): | 120/130 |
| Minimum Full Load(psig): | 60 |
| Motor Horsepower: | 50 |
| Motor Speed(RPM): | 3550 |
| BHP @ 100 psig | 46.5 |
| BHP @ full load | 51 |
| Driver rotor coupling: | Direct |
| Options: | Air Filter - Pop Up Indicator |Auto Restart |HATD Shutdown Switch |Inlet Modulation Control |Enclosure |Maintenance Kit |Microprocessor Control with Redundancy |Sequencer |Receiver 400 Gallon Vertical |Receiver 240 Gallon Vertic |
|
|
|
|
|